Power On
Once your Locker is physically installed and power connected, it will start up and perform a series of self-checks. The Locker will be ready for use when the screen displays one of the following:
Firmware 2.12.0 & Above:
Firmware 2.9.0 & Below:
Initial Configuration
The next steps will depend on the selected management and subscription options.
FUYL™ Enhanced
Follow the Getting Started instructions.
FUYL Classic (formerly Essentials & Advanced)
Follow the Onboarding the FUYL Locker instructions.
FUYL Standalone Mode
FUYL Standalone Mode operates like a hotel safe, where a bay can be freely opened when setting a PIN or RFID, and later re-opened with only that PIN or RFID. Standalone Mode offers no logging, authentication or configuration beyond simple Admin credentials.
If your Locker has firmware greater than 2.12.0 (see screenshots above) you may need to manually select "Standalone Mode" from the admin menu. To do this;
- Open the admin menu Press "00" then "OK" on the keypad.
- Enter the PIN When prompted, enter 31082018 (default).
- Select "Standalone Mode" Confirm with "OK" when prompted.
Your Locker should now display "Enter bay number" as shown above. It is recommended to change the default Admin PIN to a new 8 digit sequence and (if preferred) configure an Admin access RFID.
- Open the admin menu Press "00" then "OK" on the keypad.
- Enter the PIN When prompted, enter 31082018 (default).
- Select "Change admin credentials" And "OK".
- Choose PIN or RFID Select whether to change your Admin PIN or set an RFID. You’ll need to re-enter or confirm either.